This Landlords electrical interim checklist details what to look for to carry out an interim inspection. Split into easy to follow sections, once each task is completed you can select the checklist item item as passed (tick), failed (X) or N/A if not applicable.
Suitable for single-lets, HMOs and serviced accommodation.
Each interim checklist item describes what to look for for each section / item of the checklist.
This Landlords Interim Electrical Visual Inspection Checklist app solves the issue of providing evidence that the electrical installation is maintained and kept in a safe working order throughout a tenancy, a requirement of the new PRS scheme (Private Rented Sector).
At the end of the inspection you can save, print or email a PDF report of the routine check for your records.
Features:-
Easy to follow checklist
Save, print and email PDF reports
Sign and date reports
Add your own comments
The electrical checklist is split in to 8 easy to navigate sections:
1) Property Details
2) Paperwork
3) Consumer Unit
4) Sockets and Switches
5) Lights
6) Smoke, Heat and Carbon Monoxide Alarms
7) General
8) Additional Comments
With the new mandatory 5 yearly electrical installation condition report ( EICR ) for private rental properties (PRS) is it more important than ever to keep records of these checks for future reference should anything go wrong.
To ensure an electrical installation is continually maintained and kept in a safe working order for continued use a 5 yearly Electrical Installation Condition Report should be carried out at least every 5 years by a suitably skilled electrician, in addition to this an Interim Electrical Visual Inspection should be carried out at least every 12 months and at change of tenancy which is what this app serves.
In addition to having a 5 yearly Electrical Installation Condition Report (EICR) carried out, an Interim Visual Electrical Inspection should be carried out at least every 12 months and at change of tenant.
> Electrical Installation Condition Report: Max 5 yearly,
SOLUTION = "Pro Certs" Electrical Certification App
> Interim Electrical Inspection: 12 months / change of tenancy (which ever comes first),
SOLUTION This "Landlords Electrical Checklist" App
BS 7671 Wiring Regulations recommend an interim electrical inspection (routine check) is carried out at least every 12 months for all rental properties or at change of tenancy (which ever comes first).
Download the Landlords Electrical Checklist app today and start generating your electrical interim inspection reports.
Terms of use:- https://www.procertssoftware.com/terms-of-use
Privacy policy:- https://www.procertssoftware.com/privacy-policy
Contact support:- https://www.procertssoftware.com/contact